Carrier furnace codes are two digits flashed on a light behind the window in the lower door: count the short flashes for the first digit, then the long flashes for the second. Code 31 is the pressure switch, 33 a limit or rollout, 13 a limit lockout, 34 a flame that wasn’t proven. Bryant and Payne (now WeatherMaker) print the same codes. A repair starts with our $99 diagnostic; a flame sensor cleaning is $95 to $180 and a control board $550 to $1,180.

Our Carrier repair page has every repair price and what we’d recommend if it’s done.

Carrier furnace flash codes

Swipe to see all columns →

Swipe to see all columns →

Carrier, Bryant and Payne furnace flash codes
Code What it means What it usually takes
Rapid flashing Line voltage polarity reversed; it won’t heat A wiring fix
11 No previous code (stored codes clear after 72 hours) Nothing
12 Blower on after power up Normal
13 Limit lockout: a limit, rollout or vent switch open over 3 minutes; resets after 3 hours Airflow first; a rollout needs a look
14 Ignition lockout: 4 tries, no proven flame; resets after 3 hours Gas, igniter or flame sensor
21 Gas heating lockout Turn off power 5 minutes, retry; then call
22 Flame proved with the gas valve off Call
23 Pressure switch didn’t open A blocked tube or a stuck switch
24 24-volt fuse open A short in the thermostat or low voltage wiring
31 Pressure switch didn’t close or reopened Drain, vent, tube or inducer
32 Low-heat pressure switch didn’t close (two-stage) Drain, vent, tube or inducer
33 A limit, rollout or vent switch is open Airflow, venting or a rollout
34 Ignition proving failure Usually a flame sensor cleaning
41 Blower motor fault The blower motor or its control
45 Control circuitry lockout Cycle power; if 45 repeats, a new board

From Carrier’s 58SC0A installation instructions.

Newer Carrier furnaces show a code like 13.1

Current Carrier, Bryant and WeatherMaker furnaces print a three-character code on a small display: the first two digits are the main code above, the third narrows it down. 13.1 is a limit lockout, 14.1 an ignition lockout, 32.1 the main pressure switch open, 34.1 an ignition fault over four tries, 10.1 a polarity fault (Carrier 59SC6A manual).

The $67 Heating Check

We check your furnace, heat pump or boiler before winter. Through December 31. See the offer

Code 31: the pressure switch

Carrier’s own checklist for a pressure switch that won’t close: a plugged condensate drain, water sitting in the vent pipe, a blocked pressure tube, and a failing inducer motor. On a high-efficiency furnace the drain is the usual one, and clearing it with a trap and float switch is $175 to $420.

Codes 33 and 13: limits and rollout

33 means one of the safety switches is open right now; 13 means it stayed open over three minutes and the furnace locked out. A dirty filter or a dust-packed blower wheel ($300 to $440 to clean) trips the limit. A rollout switch is different: it trips when flame rolls out of the burners, so it needs a technician to find out why before anyone resets it.

Code 34: the flame sensor

The burners lit but the board didn’t see the flame, and Carrier’s fix list starts with cleaning the flame sensor ($95 to $180). After three more tries it becomes code 14.

Carrier furnace code questions people ask us

What does code 33 mean on a Carrier furnace?

A limit, rollout or vent switch is open. Start with the filter and airflow. If it’s the rollout switch, call: the diagnostic is $99.

What does code 31 mean on a Carrier furnace?

The pressure switch didn’t close. Usually a plugged condensate drain, water in the vent pipe, a blocked pressure tube or a failing inducer.

How do I read Carrier furnace flash codes?

Short flashes are the first digit, long flashes the second: three short and one long is 31.

Does Bryant use the same codes as Carrier?

Yes. Bryant is a Carrier company, and their 2026 furnace manuals print the identical table. See the Carrier repair page for prices.