The short answer

MrCool, Pioneer, Gree and Senville mini splits all show letter codes, but the same letters don’t mean the same thing from brand to brand. H1 is a normal defrost on a Gree and a high pressure fault on a Pioneer. On a MrCool, the code is two letters and two characters, like EL 01 for a communication fault or EL 0C for low refrigerant. Find your brand’s table, and if you’re in Northern Virginia and the code won’t clear, call before you start taking a DIY system apart.

An insulated refrigerant line set and a filter drier connected at a new outdoor unit
An insulated line set and a filter drier at a new outdoor unit on one of our installs. Every refrigerant joint has to seal tight, kit or no kit.

Check the label first

These brands share a lot of parts and look alike on the wall. The brand and model number are on the label on the side of the indoor head. Read it before you read any chart, because a code from the wrong brand’s list will send you in the wrong direction.

Free Furnace With a New AC

Put in a new AC with its matching coil and a basic single-stage gas furnace goes in with it, installed together. See the free furnace

Want your own number before anyone comes out? The HVAC estimator prices your house in a few questions.

MrCool codes (5th generation DIY)

Swipe to see all columns →

Swipe to see all columns →

Code What it means
EH 00, EH 0A The indoor board’s memory
EL 01 The indoor and outdoor units aren’t talking. On a DIY install, check the wire between them with the power off
EH 02 The zero crossing signal on the indoor board
EH 03 Indoor fan speed
EH 60, EH 61 Room sensor, indoor coil sensor
EH 0b The main board and the display board aren’t talking
EC 07 Outdoor fan speed
EH C1, EH C2 The refrigerant sensor detected a leak
EH C3 The refrigerant sensor is out of range
EL 0C Low refrigerant
PC 00, PC 08 The power module (IPM), or over current
PC 01 Voltage too high or too low
PC 02, PC 06 The compressor top or discharge is too hot
PC 03 Pressure protection
PC 04 The compressor drive
PC 0A The outdoor coil is too hot. Clear leaves and debris
PC 0F The PFC module
PC 0L Low outdoor temperature protection

Senville’s AURA series uses the same EH, EL, EC and PC families, so most of that table carries over. Check Senville’s own chart for your model.

If a MrCool shows EH C1 or EH C2: the system’s R-454B sensor found refrigerant in the room. Open windows, turn the system off at the breaker, keep flames and sparks away, and call. Don’t turn it back on to test it. Why newer systems carry that sensor is in the R-454B change.

DIY install notes from MrCool’s manual

  • The Quick Connect line set fittings go on once. Taking them apart and reconnecting can break the seal and void the warranty.
  • No Teflon tape on the fittings. Check each joint for leaks with soapy water.
  • The drain hose has to slope down with no loops or kinks, and its end can’t sit in water.
  • After a power cut or a mode change, expect about a 3 minute delay before it restarts.

The warranty terms, the electrical work and the line set rules are in our DIY mini split guide.

Pioneer codes (Diamante and Quantum)

Swipe to see all columns →

Swipe to see all columns →

Code What it means
E0 The indoor and outdoor units aren’t talking
E1, E2, E3 Room sensor, indoor coil sensor, outdoor coil sensor
E4 Refrigerant shortage or a system fault. On a new install, check both service valves are fully open
E6, EF Indoor fan, outdoor fan
E9 The power module or compressor drive
d4 The drain pan is full
F8 The reversing valve
Fy, Hd Refrigerant shortage, refrigerant leak protection
H1, H2 High pressure switch, low pressure switch
P1, P2 Voltage too high or too low, over current
P8 Outdoor temperature too high or too low
PA Heads set to different modes
A newly installed ductless mini split head high on a bedroom wall, still wrapped in its plastic
A new ductless head, still in its plastic. Its drain hose runs out the back and has to slope downhill the whole way outside.

Gree codes

Swipe to see all columns →

Swipe to see all columns →

Code What it means
E1 High pressure protection
E2 Anti-freeze protection on the indoor coil
E3 Low pressure, or a blockage
E4 The compressor discharge is too hot
E5 Over current or voltage protection
E6 The indoor and outdoor units aren’t talking. It’s the most common Gree code, usually the wire between the units
E7 Heads set to different modes
F0 Refrigerant leak or low charge
H6 No signal back from the indoor fan
U7 The reversing valve

The normal ones

Swipe to see all columns →

Swipe to see all columns →

Display Brand What it means
dF MrCool, Pioneer Defrost
H1 Gree Defrost (on a Pioneer it’s a high pressure fault)
FP MrCool Freeze protection: holds the room at 46°F while you’re away
CL Pioneer Time to clean the filters

Cold air prevention is normal on all of them: the head waits until its coil is warm before it blows, anywhere from 1 to 10 minutes. Heat range varies too. A 5th generation MrCool heats down to -13°F, and Pioneer’s Diamante heats from 5°F to 86°F outside. More in mini split not heating.

One reset, not ten. Turn the head off with the remote, switch the breaker off for about 5 minutes, then turn it back on. If the same code comes back, write it down with the model number from the label and call. Resetting a fault over and over can hide what it was protecting.

Brand by brand: Mitsubishi, Carrier, Daikin, Fujitsu, LG and Samsung. Every code family we’ve written up is on our error codes and warning lights page.

Book it

A mini split visit starts with our $99 diagnostic, and you get the repair price in writing before anything is opened. Call (703) 997-9757 or book a visit online and tell us the brand and the code or what you’re seeing. Rated 5.0 stars across 1,138 reviews on Google, Angi, Yelp, the BBB and Facebook, Virginia Class A license 2705192276.

Mitsubishi Electric, Carrier, Daikin, Fujitsu, LG, Samsung, MrCool, Pioneer, Gree and Senville are trademarks of their owners.

Questions people ask

What does EL 01 mean on a MrCool mini split?

The indoor and outdoor units aren’t communicating. On a DIY install it’s usually the wire between them. Turn the power off before you check it.

What does EH C1 mean on a MrCool?

The R-454B refrigerant sensor detected a leak. Open windows, turn the system off at the breaker, keep flames and sparks away, and call.

What does E4 mean on a Pioneer mini split?

A refrigerant shortage or a system fault. On a new install, first make sure both service valves at the outdoor unit are fully open.

What does H1 mean on a Gree mini split?

Defrost, which is normal. On a Pioneer, H1 means the high pressure switch tripped, so check the brand first.

Can I reconnect a MrCool Quick Connect line set?

MrCool says the fittings go on once. Taking them apart and reconnecting can break the seal and void the warranty.