The short answer
Six red flashes on a Trane furnace in Northern Virginia points at the power coming into it: the hot and neutral wires reversed, a poor ground, or system voltage that’s too low. On a furnace with a number display, the same group of codes adds one for the igniter. All of it is electrical work behind the panel. Don’t take the panel off, don’t flip a tripped breaker back on, and call.
What 6 flashes means on each Trane board
Swipe to see all columns →
Swipe to see all columns →
| Furnace | What you see | What Trane says it means |
|---|---|---|
| Single-stage 80% furnaces (installer guide) | Red light, 6 flashes | 115 volt power reversed, poor grounding, or system voltage too low |
| Two-stage furnaces with a red and a green light (installer guide) | Red light, 6 flashes | Line voltage polarity reversed |
| Modulating furnaces (modulating furnace guide) | Red light, 6 flashes; alert 33, 88 or 10 | Polarity reversed (33), no proper earth ground (88), or an igniter fault (10) |
| Furnaces with a number display (S9X installer guide) | E6.1, E6.2 or E6.3 | E6.1: voltage reversed polarity. E6.2: bad grounding. E6.3: the igniter relay failed or the igniter is open |
| Link furnaces (Link furnace guide) | E6.1 (ERR 033.00), E6.2 (ERR 088.00), E6.3 (ERR 010.00 or 010.01) | Polarity, grounding, and the igniter: 010.00 is an open igniter, 010.01 a failed igniter relay |
The $67 Heating Check
We check your furnace, heat pump or boiler before winter. Through December 31. See the offer
On an older furnace, 6 flashes isn’t the igniter
It’s easy to mix these up. On a single-stage Trane with one red light, a bad igniter relay is 9 flashes, not 6. On a two-stage furnace with a red and a green light, Trane’s guide gives 6 flashes to polarity alone and 9 to the inducer limit, with no flash count of its own for the igniter. Only the number displays, the Link furnaces and the modulating boards put the igniter in the 6 group. Check which board you have before you read anything into the count.
Why polarity and ground show up as a code
Trane’s two-stage guide says the control is polarity sensitive: the hot lead from the house goes to the furnace’s black lead. Its single-stage guide says the same. Swap hot and neutral, or lose a good ground, and the board flags it with 6 flashes instead of running.
What the tech checks
Trane’s charts in the S9X guide walk it through with a meter:
- E6.1, polarity. The tech measures between neutral and ground. Full line voltage there means hot and neutral are swapped, and the leads get reversed. A reading that’s off in a smaller way means a neutral or ground problem to correct, and Trane’s chart adds that the furnace must be on a dedicated circuit. If the supply checks out, the board gets replaced.
- E6.2, ground. The tech measures from the black lead to the chassis ground at the burner box. Depending on that reading, it’s the ground connections inside the furnace or the house’s earth ground.
- E6.3, the igniter. The tech watches for the igniter to glow, checks for 120 volts at the board’s igniter terminals, then the harness, then the igniter’s resistance. Trane’s range is 37 to 70 ohms at about 75 degrees. The readings decide whether it’s the board or the igniter.
If a breaker tripped
Don’t flip it back on. Trane’s page on a furnace that won’t ignite says a tripped breaker most likely means a problem with the furnace itself, and to call a pro. Its page on a furnace that keeps tripping its breaker adds that some older homes put the furnace on a circuit shared with other things, and recommends a dedicated circuit run by a licensed electrician. That matches the E6.1 chart.
What it usually comes down to
Swipe to see all columns →
Swipe to see all columns →
| Cause | What the tech finds | Typical repair |
|---|---|---|
| Reversed polarity | Hot and neutral swapped on the way into the furnace | The tech prices it after testing |
| A poor ground | A loose ground in the furnace, or a bad earth ground at the house | The tech prices it after testing |
| Low voltage or a shared circuit | Not enough power reaching the furnace | The tech prices it after testing; circuit work goes to a licensed electrician |
| The igniter | An open igniter (E6.3, or alert 10 on a modulating furnace) | $240 to $410 |
| The control board | A failed igniter relay, or a board misreading good power | $550 to $1,180 |
What you can do
- Count the flashes twice and write the number down, along with which light is flashing.
- Leave the front panel on. Trane’s page on a blinking furnace light says not to take it off while the furnace runs, and many furnaces have a door switch that cuts power and gas when it comes off. The igniter in particular: Trane’s S9X guide says not to touch it, it’s extremely hot.
- If a breaker tripped, leave it off and call.
If you smell gas, don’t touch the furnace or any switch. Leave the house and call the gas company’s emergency line from outside.

More Trane codes and fixes
- Trane furnace error codes: every light and code, board by board
- 2 flashes: the lockout after too many tries to light
- 3 flashes: the pressure switch, the vent or the drain
- 4 flashes: the limit or rollout switch
- 5 flashes: flame sensed when there should be none
- 7 flashes: the gas valve circuit
- 8 flashes: a weak flame signal
- 9 flashes: the igniter relay or the inducer limit
- Link furnace error codes: the ERR numbers on a Link thermostat
- Trane furnace blowing cold air: what to check first
- Trane heat pump not heating: the outdoor unit side of a cold house
- Emergency heat on a Trane heat pump: when to switch it on
- Trane thermostat not working: a screen or a call for heat that isn’t right
- Trane thermostat says Wait: why it pauses before it runs
- Trane repair in Northern Virginia: book a tech
The system we put in first
Built to take a beating. Put in by our crew.
Heat lamps, snow and rain on one outdoor unit: that’s Trane’s own film. We’re a Trane Comfort Specialist, on Trane’s own dealer locator, and when you pick a Trane, our crew puts it in.
Films: Trane’s own.


What a visit costs
A diagnostic visit is $99, and you get the problem and the price in writing before any work starts. Our heating check is $67 per system, through December 31: furnace, heat pump or boiler. If you want every brand’s codes and lights in one place, our error codes and warning lights guide has them.
Book it
Book the heating check, call (703) 997-9757, or book online from goswiftpro.com/cookiesoffer and a box of warm cookies comes with the visit. Rated 5.0 stars across 1,138 reviews on Google, Angi, Yelp, the BBB and Facebook, Virginia Class A license 2705192276.
Questions people ask
What does 6 flashes mean on a Trane furnace?
A power problem: the hot and neutral wires reversed, a poor ground, or system voltage too low. On a modulating furnace, 6 flashes can also be the igniter.
Is 6 flashes the igniter on a Trane furnace?
Not on an older single-stage board. There, a bad igniter relay is 9 flashes. On a furnace with a number display, the igniter is E6.3, in the same group as polarity and ground.
What is E6.1 on a Trane furnace?
Voltage reversed polarity: hot and neutral are swapped. E6.2 is bad grounding and E6.3 is the igniter or its relay.
My furnace tripped a breaker. Should I reset it?
No. Trane says a tripped breaker most likely means a problem with the furnace itself. Leave it off and call.
How much does it cost to fix 6 flashes on a Trane furnace?
The diagnostic is $99. An igniter runs $240 to $410 and a control board $550 to $1,180. Wiring and ground fixes are priced in writing after testing.

