The short answer

On a Trane Link furnace in Northern Virginia, a fault shows up two ways: a short E code on the furnace’s own display, and a longer ERR number on the thermostat, like ERR 022.01. Both come from the same table in Trane’s Link furnace guide, and we’ve sorted it by the ERR number so you can find yours. Most are a call for a tech; a few start with a filter, a vent pipe or a drain you can check yourself.

Where the codes show up

Per Trane’s Link furnace guide, the board’s display only has room for two digits, so it shows the main code and a tech reads the full one over Bluetooth with Trane’s Technician app. The thermostat shows them too; Trane’s guide names the SC360 and the UX360. Err 126 is a different thing, lost communication: our Err 126 guide covers it.

Trane’s table prints a few as 01.05 or 04.00, its charts as 001.05 or 004.00. Same codes.

The $67 Heating Check

We check your furnace, heat pump or boiler before winter. Through December 31. See the offer

Every Link furnace code, by ERR number

Swipe to see all columns →

Swipe to see all columns →

ERR on the thermostat Furnace shows What Trane says Where to start
001.02 E3.4 Second stage pressure switch open Vents and drain, then call (guide)
001.03 E3.3 Second stage pressure switch shorted Call
001.04 E3.2 First stage pressure switch open Vents and drain, then call (guide)
001.05 E3.1 First stage pressure switch shorted Call
004.00 E8.0 Low flame sense; still running Usually the flame sensor (guide)
SOP 004.50 E28 Supply air thermistor out of range Call
SOP 004.52 E27 Return air thermistor out of range Call
010.00 E6.3 Igniter open Call (guide)
010.01 E6.3 Igniter relay failed Call (guide)
018.00 E1.0 Internal failure of the control board Call
018.05 E9.4 A control board that doesn’t match the furnace Call
022.00 E2.2 Recycles exceeded; one hour lockout The filter, then call (guide)
022.01 E2.1 Retries exceeded; one hour lockout The filter, then call (guide)
022.02 E2.3 First stage gas valve not powered when it should be, 10 times Call (guide)
022.04 E3.5 Second stage pressure switch open with the second stage gas valve powered Call
026.00 E4.1 Reverse airflow limit open The filter, then call (guide)
026.01 E4.0 High limit open The filter, then call (guide)
026.02 E9.1 Inducer limit open Vents outside, then call (guide)
026.06 E9.2 Condensate pressure switch open The drain (guide)
026.07 E9.3 Condensate lockout; one hour The drain (guide)
033.00 E6.1 Voltage reversed polarity Call (guide)
034.00 E5.0 Flame detected, should not be present Leave it off and call (guide)
087.00 E4.2 Rollout limit open Call (guide)
088.00 E6.2 Bad grounding Call (guide)
091.00 E17 Blower motor not answering the control Call
091.01 E10 A motor control lost communication with the furnace control Call
091.07 E24 Lost communication between two of the furnace’s control boards Call
091.08 E10 Inducer control board or inducer motor failed Call
091.12 E18 The control lost communication with the blower Call
092.00 E12 Open fuse Call
093.00 E11 A gas valve not powered when it should be Call (guide)
093.01 E7.1 or E11 A gas valve powered without a call for heat Call (guide)
093.02 E11 The redundant relay output not powered when it should be Call (guide)
093.03 E7.2 The redundant relay output on when it should be off Call (guide)
093.04 E11 Gas valve relay stuck closed Call (guide)
094.00 E24 Communication lost inside the furnace Call
114.02 E13 Blower motor ID doesn’t match the furnace Call
114.08 None No model number programmed into the board Call
114.09 None Invalid model number Call
114.10 E14 Configuration file error Call
161.03 E26 Return static pressure sensor out of range Call
161.04 E25 Accelerometer out of range or not responding Call
None E23 Menu settings not received Call
A SwiftPro technician in a blue company polo holding a drill beside a new Trane outdoor unit at a Northern Virginia home
One of our techs with a drill beside a new Trane outdoor unit.

The one hour lockouts

Per Trane’s charts, three of these stop the furnace for an hour: ERR 022.01 after 6 failed tries to light in one call for heat, ERR 022.00 after the flame drops out 10 times, and ERR 026.07 after the condensate switch opens 5 times. Other boards count differently: see our Trane furnace error codes guide.

What Trane’s charts point to

  • Pressure switch codes (ERR 001.02 to 001.05). Trane’s chart says that in most cases the pressure switch isn’t the problem. Our 3 flashes guide covers the vent, the inducer and the drain.
  • Condensate codes (ERR 026.06 and 026.07). Trane says these are normally caused by a stoppage of condensate outside the furnace, so the drain line is the first place to look.
  • Blower communication codes (E17 and E18). Most likely a loose low voltage control wiring connection, per Trane’s chart.

What you can do

  • Write down the full number, decimals and all.
  • Check the filter. It’s on Trane’s lockout list of causes, and it’s the one thing Trane says to try yourself.
  • For a pressure switch or inducer limit code, check that snow, ice and leaves aren’t blocking the white plastic vent pipes outside.
  • Leave the front panel on. Trane’s page on a blinking furnace light says not to take it off while the furnace runs, and many furnaces have a door switch that cuts power and gas when it comes off.
  • Don’t keep resetting it. A code that comes back means the cause is still there.

If you smell gas, don’t touch the furnace or any switch. Leave the house and call the gas company’s emergency line from outside.

Open furnace cabinet with blower and control board visible
An open furnace with the blower and control board.

More Trane codes and fixes

What a visit costs

A diagnostic visit is $99, and you get the problem and the price in writing before any work starts. Our heating check is $67 per system, through December 31: furnace, heat pump or boiler. If you want every brand’s codes and lights in one place, our error codes and warning lights guide has them.

Book it

Book the heating check, call (703) 997-9757, or book online from goswiftpro.com/cookiesoffer and a box of warm cookies comes with the visit. Rated 5.0 stars across 1,138 reviews on Google, Angi, Yelp, the BBB and Facebook, Virginia Class A license 2705192276.

Questions people ask

Where do I find the error code on a Trane Link furnace?

On the furnace’s display, which shows a short E code, and on the thermostat, which shows the longer ERR number. A tech reads the full code over Bluetooth with Trane’s app.

What does ERR 022.01 mean on a Trane thermostat?

Retries exceeded: the furnace failed to light 6 times in one call for heat and locked out for an hour. Check the filter, then call if it comes back.

What does ERR 026.06 mean on a Trane thermostat?

The condensate pressure switch opened. Trane says it’s normally a stoppage of condensate outside the furnace, so the drain line comes first.

What is a Trane Link furnace?

A communicating Trane furnace that reports its faults to the thermostat. Trane’s Link guide covers the kit that turns its S9V2 furnace into one.

How much does it cost to fix a Trane Link furnace error?

The diagnostic is $99. A flame sensor cleaning runs $95 to $180, a condensate drain repair $175 to $420, and a control board $550 to $1,180.

The system we put in first

Built to take a beating. Put in by our crew.

Heat lamps, snow and rain on one outdoor unit: that’s Trane’s own film. We’re a Trane Comfort Specialist, on Trane’s own dealer locator, and when you pick a Trane, our crew puts it in.

Films: Trane’s own.

Trane's film: a Trane outdoor unit on a dark lab stage under the Trane logo and "It's Hard To Stop A Trane."
Trane's film: a Trane outdoor unit under a spotlight against a bare wall.