The short answer

Eight red flashes on a Trane furnace in Northern Virginia means the flame signal is weak. The furnace is still running, so you probably still have heat, but the board is telling you it can barely read its flame. Usually that’s the flame sensor. If the board loses the flame altogether, it shuts the gas off and tries again, and enough failed tries ends in a lockout and a cold house. Book it now, while it still heats.

What 8 flashes means on each Trane board

Swipe to see all columns →

Swipe to see all columns →

Furnace What you see What Trane says it means
Single-stage 80% furnaces (installer guide) Red light, 8 flashes Low flame sense signal
Two-stage furnaces with a red and a green light (installer guide) Red light, 8 flashes Weak flame
Modulating furnaces (modulating furnace guide) Red light, 8 flashes; alert 4 Flame current is low, but still strong enough to run
Furnaces with a number display (S9X installer guide) E08 Flame current is low, but still strong enough to allow operation
Link furnaces (Link furnace guide) E8.0 (ERR 004.00) Low flame sense

The $67 Heating Check

We check your furnace, heat pump or boiler before winter. Through December 31. See the offer

What the flame sensor does

Trane’s page on a furnace that shuts off after it lights puts it simply: the flame sensor makes sure the gas valve only stays open while there’s a flame burning. A dirty sensor can’t prove the flame is there, so the furnace shuts off early. Eight flashes is the board reading that signal as low but still good enough to run.

The numbers behind it

The board reads the flame as a tiny electrical current. Trane’s S9X wiring diagram gives the acceptable range as 0.75 to 3 microamps, and its chart for E08 starts when the reading is under 0.5. A tech reads it at the board’s test pads with a meter, so it’s a measured answer, not a guess.

Gas furnace cabinet opened with the blower out and wiring visible
A furnace with the blower pulled out.

What the tech checks

Trane’s E08 chart goes in this order:

  • The flame itself. It should be a tight pattern going into the heat exchanger. Trane notes that burners without enough air tend to roll back.
  • Where the sensor sits. It has to be in the flame, where it belongs.
  • The sensor. If the flame and the position check out, the sensor gets replaced.
  • The wiring. If the current reads fine after that, the wiring and connections get checked.

What it usually comes down to

Swipe to see all columns →

Swipe to see all columns →

Cause What the tech finds Typical repair
A dirty flame sensor A low reading that comes back up once it’s cleaned $95 to $180 cleaned
A worn sensor A low reading that cleaning doesn’t fix $240 to $410 replaced
The burner flame Burners rolling back instead of a tight pattern The tech prices it after testing
The wiring A loose connection between the sensor and the board The tech prices it after testing

Why fix it now

Eight flashes still gives you heat, but Trane’s two-stage guide spells out what happens if the flame drops out during a cycle: the board shuts the gas, tries to relight, and locks out if it can’t. That’s 2 flashes, usually on the coldest night of the week. Trane’s page on a furnace blowing cold air also notes that with a flame sensor problem the blower can keep going and send cool air, which our Trane furnace blowing cold air guide covers.

What you can do

  • Count the flashes twice and write the number down, along with which light is flashing.
  • Check the filter. When a furnace locks out, Trane’s lockout page says changing the filter is the only thing to try yourself, and a dirty one is on its list of causes.
  • Leave the flame sensor to a tech. Trane’s page on a furnace that won’t ignite says not to clean or replace it yourself.
  • Leave the front panel on. Trane’s page on a blinking furnace light says not to take it off while the furnace runs, and many furnaces have a door switch that cuts power and gas when it comes off.

If you smell gas, don’t touch the furnace or any switch. Leave the house and call the gas company’s emergency line from outside.

Don’t confuse it with 5 flashes

Five flashes is the board seeing flame where there should be none, and that’s a safety call. Eight is the opposite: a real flame with a weak signal. Our flame sensor guide covers the part itself on any brand.

Two SwiftPro technicians in a Northern Virginia utility room, at the open furnace with the tank water heater behind them
Two of our techs at an open furnace, with the tank water heater behind them.

More Trane codes and fixes

The system we put in first

Built to take a beating. Put in by our crew.

Heat lamps, snow and rain on one outdoor unit: that’s Trane’s own film. We’re a Trane Comfort Specialist, on Trane’s own dealer locator, and when you pick a Trane, our crew puts it in.

Films: Trane’s own.

Trane's film: a Trane outdoor unit on a dark lab stage under the Trane logo and "It's Hard To Stop A Trane."
Trane's film: a Trane outdoor unit under a spotlight against a bare wall.

What a visit costs

A diagnostic visit is $99, and you get the problem and the price in writing before any work starts. Our heating check is $67 per system, through December 31: furnace, heat pump or boiler. If you want every brand’s codes and lights in one place, our error codes and warning lights guide has them.

Book it

Book the heating check, call (703) 997-9757, or book online from goswiftpro.com/cookiesoffer and a box of warm cookies comes with the visit. Rated 5.0 stars across 1,138 reviews on Google, Angi, Yelp, the BBB and Facebook, Virginia Class A license 2705192276.

Questions people ask

What does 8 flashes mean on a Trane furnace?

A weak flame signal. The furnace is still running, but the board can barely read its flame. Usually it’s the flame sensor.

What is E08 on a Trane furnace?

The same warning on a furnace with a number display: flame current is low, but still strong enough to run. On a Link furnace it’s E8.0, ERR 004.00 on the thermostat.

Can I keep running my furnace with 8 flashes?

It still heats for now. Book a visit soon, because if the board loses the flame it shuts the gas and can lock out.

Can I clean the flame sensor myself?

Trane says not to clean or replace the flame sensor yourself. Change the filter if it’s dirty and leave the sensor to a tech.

How much does it cost to fix 8 flashes on a Trane furnace?

The diagnostic is $99. A flame sensor cleaning runs $95 to $180 and a new sensor $240 to $410.