The short answer
A Trane furnace in Northern Virginia blowing cold air comes down to a short list: the fan set to On instead of Auto, a clogged filter, a safety that’s stopped the burners while the blower keeps running, or a part like the flame sensor. Check the thermostat and the filter first. Then count the red flashes on the furnace’s light. That number tells you which safety tripped, and whether it’s a quick fix or a call.
1. The fan setting
Trane’s page on a furnace blowing cold air starts here: set to On, the fan blows cold air when the furnace isn’t running. Switch it to Auto and the fan runs with the heat.
The $67 Heating Check
We check your furnace, heat pump or boiler before winter. Through December 31. See the offer
2. The thermostat
Make sure it’s on Heat and set warmer than the room, per Trane’s page on a furnace that won’t ignite. A blank or dead screen is its own problem, covered in our blank screen and thermostat not working guides. If the thermostat shows it’s calling for heat and the furnace still blows cold, the trouble’s at the furnace.
3. The filter
A dirty filter can make the furnace overheat until the limit switch shuts it off, per Trane’s page on a furnace that shuts off after it lights. Trane’s cold air page adds that a high limit switch worn out by repeated overheating can leave the furnace blowing cool air all the time. Trane says to change the filter every one to three months, and when a furnace locks out, its lockout page says the filter is the one thing to try yourself. Our filter guide covers which one to buy.
4. Read the light on the furnace
Look through the window in the furnace’s lower door and count the red flashes. The ones that go with cold air:
- 2 flashes: a lockout after too many tries to light. Trane’s lockout page says the first one or two are soft lockouts, and after that a hard one (what 2 flashes means).
- 4 flashes: the limit switch opened because the furnace ran too hot. Start with the filter (what 4 flashes means).
- 3 flashes, or E09 on a number display: a pressure switch, which on a furnace with a condensate drain can be a clogged drain. Trane’s cold air page says a clog in the drain line trips a safety that keeps the burners from lighting, so the fan sends cool air. Our 3 flashes guide covers the drain, and 9 flashes covers E09.
- 8 flashes: a weak flame signal, usually the flame sensor (what 8 flashes means). Trane’s cold air page notes that with a flame sensor problem the blower can keep going and send cool air.
- Anything else: every count and code is in our Trane furnace error codes guide, and the ERR numbers on a Link thermostat are in our Link codes guide.
5. The gas supply
Trane’s cold air page says the gas valve sometimes gets bumped. Its page on a furnace that won’t ignite says the furnace’s gas shutoff is on the pipe within a few feet of the furnace and should be in the on position. If it’s off and you don’t know why, call.
If you smell gas, don’t touch the furnace or any switch. Leave the house and call the gas company’s emergency line from outside.
6. One room cold, the rest fine
That points at the ducts more than the furnace. Trane’s cold air page says leaky ductwork can keep one room cold. Our guide to a system blowing cold air in winter covers it on any brand, and if your Trane is a heat pump, start with Trane heat pump not heating.
What not to do
- Don’t clean the flame sensor yourself. Trane’s page on a furnace that won’t ignite says to leave it to a pro.
- If a breaker tripped, don’t flip it back on. Trane says it most likely tripped because of a problem with the furnace itself.
- Leave the front panel on. Trane’s page on a blinking furnace light says not to take it off while the furnace runs, and many furnaces have a door switch that cuts power and gas when it comes off.
- Trane’s cold air page also notes that working on a furnace still under warranty yourself can void the warranty.
What the fix costs
Swipe to see all columns →
Swipe to see all columns →
| Cause | Typical repair |
|---|---|
| Fan set to On | Nothing to fix: switch it to Auto |
| A clogged filter | A new filter |
| A dirty flame sensor | $95 to $180 cleaned, $240 to $410 replaced |
| A clogged condensate drain | $175 to $420 |
| The igniter | $240 to $410 |
| The control board | $550 to $1,180 |
| A worn high limit switch | The tech prices it after testing |
If the filter was the problem, look at the blower too. Our heating check is $67, and on a furnace, for $229, we also pull the blower wheel and clean it blade by blade, fit a new filter, set your dampers for winter and tune the furnace, through December 31.
More Trane codes and fixes
- Trane furnace error codes: every light and code, board by board
- 2 flashes: the lockout after too many tries to light
- 3 flashes: the pressure switch, the vent or the drain
- 4 flashes: the limit or rollout switch
- 5 flashes: flame sensed when there should be none
- 6 flashes: polarity, ground or the igniter
- 7 flashes: the gas valve circuit
- 8 flashes: a weak flame signal
- 9 flashes: the igniter relay or the inducer limit
- Link furnace error codes: the ERR numbers on a Link thermostat
- Trane heat pump not heating: the outdoor unit side of a cold house
- Emergency heat on a Trane heat pump: when to switch it on
- Trane thermostat not working: a screen or a call for heat that isn’t right
- Trane thermostat says Wait: why it pauses before it runs
- Trane repair in Northern Virginia: book a tech
The system we put in first
Built to take a beating. Put in by our crew.
Heat lamps, snow and rain on one outdoor unit: that’s Trane’s own film. We’re a Trane Comfort Specialist, on Trane’s own dealer locator, and when you pick a Trane, our crew puts it in.
Films: Trane’s own.


What a visit costs
A diagnostic visit is $99, and you get the problem and the price in writing before any work starts. Our heating check is $67 per system, through December 31: furnace, heat pump or boiler. If you want every brand’s codes and lights in one place, our error codes and warning lights guide has them.
Book it
Book the heating check, call (703) 997-9757, or book online from goswiftpro.com/cookiesoffer and a box of warm cookies comes with the visit. Rated 5.0 stars across 1,138 reviews on Google, Angi, Yelp, the BBB and Facebook, Virginia Class A license 2705192276.
Questions people ask
Why is my Trane furnace blowing cold air?
Check the fan setting first: On blows air even when the furnace isn’t heating. Then the filter, then the red light on the furnace, which tells you which safety tripped.
Should the furnace fan be on Auto or On?
Auto, if the cold air bothers you. On runs the fan all the time, so it blows unheated air between heating cycles.
Can a dirty filter make a furnace blow cold air?
Yes. A clogged filter can overheat the furnace until the limit switch shuts the burners off. Trane says changing the filter is the one fix to try yourself.
Can a clogged condensate drain make a furnace blow cold air?
Yes. Trane says a clogged drain line trips a safety that keeps the burners from lighting, so the fan sends cool air. A tech clears the line and the pan and checks the pump.
How much does it cost to fix a Trane furnace blowing cold air?
The diagnostic is $99. A flame sensor cleaning runs $95 to $180, a condensate drain repair $175 to $420, and a control board $550 to $1,180.