The display
Navien tankless error codes,
E003 to E788, and what each means
When a Navien stops, it shows an E-number on the front panel. Write it down, press the Back button once to reset, and if the code comes back, find it below.
Navien NPE-A2 and NPE-S2 condensing tankless: codes you can check first
Navien’s user manual gives an owner step for each of these.
Navien NPE-2 tankless error codes with an owner step| Code | What it means | What to do |
|---|
| E003 | Ignition failure: the burner didn’t light | Make sure the gas valve to the heater is fully open |
|---|
| E004 | False flame: the board sees a flame that isn’t there | Make sure the power cord is properly grounded |
|---|
| E012 | Flame loss: it lit, then went out | Clean the intake air filter; check the cord is grounded |
|---|
| E016 | The heat exchanger is overheating | Clean the cold water inlet filter; the heat exchanger needs a flush |
|---|
| E030 | Exhaust overheating: it shuts down when the flue passes 149°F | Clean the cold water inlet filter; the heat exchanger needs a flush |
|---|
| E109 | The fan motor isn’t running right | Clean the intake air filter |
|---|
| E110 | Abnormal air pressure | Clear the exhaust pipe outside and clean the intake air filter, which Navien says to do every 3 to 4 months |
|---|
| E515 | Control board fault | Check the cord is grounded; if it stays, the board needs a look |
|---|
| E760 | Flushing and service alarm | It’s due for routine service: Navien says call your installer |
|---|
Source: Navien NPE-2 User’s Information Manual. Codes vary by model and control board: the chart printed on your unit, or its manual, is the final word.
Navien NPE-A2 and NPE-S2: codes that need a pro
For each of these, Navien’s manual says contact its technical support, and Navien points owners to their installer for the repair.
Navien NPE-2 tankless error codes for a technician| Code | What it means | What to do |
|---|
| E031 | The burner is overheating | Leave it off and call |
|---|
| E047 | Exhaust temperature sensor open or shorted | A sensor or wiring repair |
|---|
| E407 | Hot water outlet temperature sensor open or shorted | A sensor or wiring repair |
|---|
| E421 | Cold water inlet temperature sensor open or shorted | A sensor or wiring repair |
|---|
| E434 | The water adjustment valve isn’t working right | A valve repair |
|---|
| E439 | The flow sensor isn’t working right | A flow sensor cleaning or replacement |
|---|
| E445 | The bypass mixing valve isn’t working right | A valve repair |
|---|
| E762 | The vent pipe isn’t fully inserted | Leave it off and call: the venting gets reseated |
|---|
| E773 | It’s running on the wrong gas | Leave it off and call |
|---|
| E788 | The gas type set on the board doesn’t match the panel | Call: both get set to the gas you have |
|---|
Source: Navien NPE-2 User’s Information Manual. Codes vary by model and control board: the chart printed on your unit, or its manual, is the final word.