A SwiftPro heating technician carrying an electric heat strip assembly, the backup heat inside a heat pump's air handler, through a Northern Virginia home
Bryant furnaces · Air conditioners · Heat pumps · Evolution · Northern Virginia

Bryant furnace and AC repair
in Northern Virginia

A Bryant furnace or AC repair starts with the $99 diagnostic, and most Bryant furnace, AC and heat pump repairs run $95 to $1,500, priced in writing before anything is touched. Bryant is a Carrier company, so when yours is done, we’ll price a Carrier and a Trane side by side.

Get your price in writing

Send this and the office calls or texts you back to set a time.

This field is for validation purposes and should be left unchanged.

We’ll call or text this number about your request. By sending it you agree to our terms and privacy policy.

Rather talk now? (703) 997-9757

  • Evolution, Preferred and Legacy lines, gas or propane
  • Bryant is a Carrier company, and we’re on Carrier’s dealer locator
  • The fault found and the price in writing before any work

5.0 stars across 1,132 reviews

Licensed and insuredVirginia Class A contractor #2705192276

24/7 emergency serviceOften same-day, and we will tell you honestly when we can get there.

Our own HVAC installersA dedicated heating and cooling team, separate from our plumbers

Price in writing firstYou see every option priced before anything is ordered

Read your own Bryant

What your Bryant is doing,
and what it usually means

The things people describe on the phone, what they turn out to be on a Bryant, and what the fix costs.

The furnace runs but the air is cold

The burners lit and went out, or never lit. On a Bryant that’s usually a sooted flame sensor ($95 to $180 to clean) or a cracked igniter ($240 to $410). The board’s light will be flashing a code; the table below says which. Count the flashes: the short ones are the first digit and the long ones the second. Three short and four long is code 34: the burners lit but the flame wasn’t proven, and Carrier’s fix list starts with cleaning the flame sensor.

It starts, runs a minute, then shuts off

A furnace that keeps restarting is protecting itself: a dirty flame sensor, a clogged filter tripping the high limit, or a pressure switch that can’t prove the venting. Start with the filter. Then count the flashes.

The outdoor unit hums but the fan won’t spin

Most of the time it’s the run capacitor ($240 to $370). Turn it off at the thermostat: a compressor that keeps trying to start against a dead capacitor can burn itself out.

Ice on the copper lines or the outdoor coil

In summer, ice means the coil isn’t getting enough air (a filter, a dirty blower wheel at $300 to $440) or it’s low on refrigerant, which means a leak. On a heat pump in winter, some frost is normal; a solid block of ice that never clears points at the defrost board ($450 to $1,150).

Water on the floor around the furnace

A high-efficiency furnace and every AC coil make water, and it has to drain. A clogged trap or drain line ($175 to $420 to clear, with a float switch added) is the usual answer. Water from the tank beside it is a water heater call. On a condensing Bryant, a plugged drain can show up first as pressure switch code 31 or 32.

Squealing, banging or a loud hum inside

A squeal or whine is usually the inducer or the blower motor’s bearings on the way out (a blower motor runs $670 to $2,400, standard against variable speed). A bang at startup is delayed ignition: gas building up before it lights. That one needs a look soon, not next month.

It runs all day and the bills jumped

A system that never shuts off is short on capacity: low refrigerant, a dirty outdoor coil, a blower wheel packed with dust, or a heat pump leaning on its backup electric heat. Each one is a price, not a guess.

You smell gas

Leave the house, then call the gas company from outside. Once it’s safe, call us: (703) 997-9757, 24/7.

The codes on the board

Bryant furnace and AC codes,
and what each means

A Bryant furnace flashes a two-digit code on a light you can see through the window in the lower door: count the short flashes for the first digit and the long flashes for the second. Write it down before you reset anything.

Bryant furnace flash codes (31, 33 and the rest)

From Bryant’s 2026 manual for the Legacy 96 (916SA), the same table Carrier prints for its matching furnace. The light flashes the two-digit code; a small display on the board adds a third digit, like 33.1.

Bryant furnace flash codes
CodeWhat it meansWhat it usually takes
Rapid flashingLine voltage polarity reversed (10.1): the furnace won’t heatA wiring fix
13Limit lockout: a switch in the main limit circuit stayed open over 3 minutesAirflow first: the filter and the blower
14Ignition lockout after 4 tries in a rowGas supply, igniter or flame sensor
22False flame: flame sensed when there shouldn’t be oneCall
24Fuse fault: the 24-volt fuse is openA shorted low-voltage wire, thermostat wires included
31The secondary pressure switch is open; 31.3 is a lockout after three triesA plugged condensate drain, water in the vent pipe, a blocked pressure tube or the inducer
32The main pressure switch is openThe same list: the drain, the venting, the tubing or the inducer motor
33A switch opened in the main limit circuitA dirty filter or restricted ductwork first
34Ignition fault: the burners lit but the flame wasn’t provenUsually a flame sensor cleaning
45Control failure: the gas valve relay won’t closeCycle the power; if 45 comes back, a new board

Source: Bryant 916SA installation instructions. Codes vary by model and control board: the chart printed on your unit, or its manual, is the final word.

Bryant Evolution variable-speed AC and heat pump codes (on the thermostat)

The Evolution Extreme 191VAN air conditioner and the 290VAN, 291VAN and 293VAN heat pumps report a fault to the thermostat as a pair of numbers.

Bryant Evolution outdoor unit fault codes
CodeWhat it meansWhat it usually takes
14-94Line voltage low: incoming power dropped below 180 voltsThe power supply, the disconnect or the wiring
18-11Not enough airflow across the indoor coil, or a low refrigerant chargeThe filter and ductwork first, then the charge
31-16High pressure switch shutdown; three of them lock it out for 2 hoursA dirty outdoor coil or the outdoor fan
31-58Compressor high pressure lockoutA dirty condenser, blocked airflow, an overcharge or the expansion valve
32-59Low pressure lockoutBryant’s manual says most likely a refrigerant leak
38-13The drive can’t get the compressor turningCompressor damage or a high pressure difference: a technician’s call
39-13Fan start errorThe outdoor fan motor
41-13Defrost timed out before the coil warmed upHeavy ice, a loose coil sensor, or high wind cooling the coil
61-13Reversing valve timeout (heat pumps)The reversing valve or its coil
86-06The inverter drive stopped talking to the controlWiring or a board

Source: Bryant Evolution variable-speed service manual. Codes vary by model and control board: the chart printed on your unit, or its manual, is the final word.

What it costs

What a Bryant repair
costs in Northern Virginia

Our own repair prices, by part, priced exactly like a Carrier. Carrier, Bryant’s parent company, lists capacitors, blower motors, contactors, condenser fans, igniters, flame sensors and drain lines among the parts that wear out most. Tap a system to narrow the list.

Flame sensor cleaned

The thin rod that proves the burners lit. Coated in soot, it tells the board the flame went out, and the gas shuts off a few seconds after the burners light.

$95 to $180

Condensate drain cleared, trap and switch added

High-efficiency furnaces and every AC coil make water. When the drain or trap clogs, a float switch stops the system on purpose so the water doesn’t end up in the ceiling.

$175 to $420

Refrigerant topped up

One to three pounds. If it needs it again next season it’s leaking, and topping it up every year is the expensive way to lose.

$190 to $740

Run capacitor replaced

The part that kicks the compressor and fan motors into turning. The single most common reason an outdoor unit hums and never starts.

$240 to $370

Igniter or flame sensor replaced

A cracked hot surface igniter glows weakly or not at all, so the burners never light. Usually on the van.

$240 to $410

Contactor replaced

The relay that sends power to the outdoor unit. Burnt or stuck points mean it sits silent while the thermostat calls, or runs when it shouldn’t.

$290 to $425

Blower wheel pulled and cleaned

A wheel caked in dust moves a fraction of the air it should: weak airflow, a frozen coil, a furnace tripping its limit.

$300 to $440

Thermostat replaced

Standard through smart, wired and set up for the system it runs.

$300 to $640

Defrost board replaced

Heat pumps only: the board that decides when to melt the ice off the outdoor coil.

$450 to $1,150

Control board replaced

The brain in the furnace or air handler. When it goes, nothing downstream of it does what it’s told.

$550 to $1,180

Blower motor replaced

The indoor fan motor. The spread is a standard motor against a variable-speed one.

$670 to $2,400

Condenser fan motor replaced

The fan on top of the outdoor unit. If it stops while the compressor runs, the repair gets more expensive by the minute.

$1,100 to $1,500

Refrigerant leak found and repaired

Finding it, fixing it, then recharging the system.

$1,850 to $2,700

or $31/mo at 0% APR for 60 months

Compressor replaced, part under warranty

Labor and refrigerant, when the manufacturer still covers the compressor.

$1,900 to $2,500

or $32/mo at 0% APR for 60 months

Compressor replaced, out of warranty

The big one, and usually the point where replacing the system wins. You get both numbers.

$2,200 to $5,100

or $37/mo at 0% APR for 60 months

Monthly figures: 60mo @ 0% APR on each starting price, the whole price financed, on approved credit. Longer plans lower the payment and cost more in total. The lender sets the final terms. How financing works

Comfort+ members get the $99 diagnostic included in the visit, 15% off any service, and 50% of each repair bill banked toward replacing that system, up to $1,500. How Comfort+ works.

Fix it or replace it

How old your Bryant is,
and when a repair stops making sense

The serial number on the rating plate gives the year it was built. Here’s how to read it.

On a Bryant air conditioner or heat pump, the first two digits of the serial number are the week it was built and the next two the year: 2218E… is week 22 of 2018 (Bryant service manual). The model number says which it is: one that starts with 1 is an air conditioner, 2 a heat pump. Bryant’s furnace manuals don’t spell out a date rule, so match the furnace to the outdoor unit or the install invoice.

Consumer Reports members expect a gas furnace to last a median of 20 years and central air about 15 (gas furnaces, 2024; central air, 2025). What shortens that: how long a furnace lasts.

  • Fix it when the problem is a part: an igniter, flame sensor, capacitor, contactor, pressure switch, board or motor. Most of those land at $95 to $1,500, and you get the price in writing first.
  • Think about replacing it when the compressor or the furnace’s heat exchanger fails out of warranty, when the Bryant is past about 15 years and the repair is a big one, or when it needs refrigerant every year.
  • A cracked heat exchanger is a stop. It can put carbon monoxide in the house. We’ll show it to you, with a camera if it’s buried, before anyone says the word replace.

Gas furnace alone

$4,285 to $14,040

or $71/mo at 0% APR for 60 months

Keeping the AC you have. By size and efficiency, installed.

Furnace and AC together

$8,898 to $23,000

or $148/mo at 0% APR for 60 months

2 to 5 ton, matched, installed with the permit.

Heat pump system

$8,499 to $21,650

or $142/mo at 0% APR for 60 months

Heat pump and air handler, 2 to 5 ton, installed.

Monthly figures: 60mo @ 0% APR on each starting price, the whole price financed, on approved credit. Longer plans lower the payment and cost more in total. The lender sets the final terms. How financing works

Want your own number before anyone comes out? The HVAC estimator prices your house in a few questions.

A Bryant air conditioner condenser on a rubber pad beside a vinyl-sided Northern Virginia house, on a SwiftPro service call

A Bryant air conditioner on its pad beside a Northern Virginia house, on one of our service calls.

When it’s time for a new one

Bryant is Carrier. We’ll price
a Carrier or a Trane

We install Carrier and Trane, not Bryant. Since Bryant is a Carrier company, that puts the same family of equipment beside our first pick, priced side by side in writing.

  • You can check us on Carrier’s own site. We’re on Carrier’s dealer locator as Carrier experts in Chantilly, and on Trane’s as a Trane Comfort Specialist.
  • Same size, same scope, two prices. Trane is our first pick for most houses here, and a Carrier is a fair choice beside it. You see both in writing, so the only difference left is the equipment.
  • What owners say. In Consumer Reports’ 2022 central air survey of 23,997 systems, Bryant and Carrier were among five brands rated Excellent for owner satisfaction, and Trane was the only one of 21 rated Excellent for both predicted reliability and owner satisfaction (Consumer Reports, 2022).
  • Two years of our labor on every install, on top of the manufacturer’s parts warranty. We buy Trane through Ferguson.
A Carrier gas furnace with its coil and flue above it in a Northern Virginia basement, a media air cleaner cabinet on its return side, on a SwiftPro job

A Carrier gas furnace, from the same company as Bryant, with its coil and flue in a Northern Virginia basement on one of our jobs.

The system we put in first

Built to take a beating. Put in by our crew.

Heat lamps, snow and rain on one outdoor unit: that’s Trane’s own film. We’re a Trane Comfort Specialist, on Trane’s own dealer locator, and when you pick a Trane, our crew puts it in.

Films: Trane’s own.

Trane's film: a Trane outdoor unit on a dark lab stage under the Trane logo and "It's Hard To Stop A Trane."
Trane's film: a Trane outdoor unit under a spotlight against a bare wall.

The warranty

Is your Bryant still
under warranty?

Maybe, and the serial number tells us. Here’s how Bryant’s warranty works.

  • Outdoor units: 10 years on parts and the compressor when registered within 90 days, 5 if not. The next owner gets 5 years without registering. Labor and refrigerant aren’t covered.
  • Evolution Extreme unit replacement: if the compressor fails from a defect, a one-time new outdoor unit, on the 191VAN air conditioner and the 290VAN, 291VAN and 293VAN heat pumps (10 years registered, 5 if not). Bryant’s certificate words it for the original purchaser, so if the house came with one, don’t count on it.
  • Furnace heat exchanger: a limited lifetime for the original owner on Evolution 90%+, Preferred 96 and 97 and Legacy 96 furnaces registered within 90 days, 20 years if not; 20 years on the rest. Parts: 10 years registered, 5 if not.
  • Red Shield, on Evolution furnaces (987M, 987T, 986T, 880T, 881T): a one-time new furnace if the heat exchanger fails within 10 years when registered, 5 if not. It’s for the original purchaser and needs Bryant’s pre-approval (Red Shield certificate).
  • Two old issues worth knowing: a 2007 settlement added a 20-year parts and labor warranty on the secondary heat exchanger of 90%+ Carrier, Bryant, Payne and Day & Night furnaces built after 1989 (Carrier denied the claims; ACHR News), and a 2017 recall replaced the fuse boards, whose capacitors could overheat, on about 23,300 Carrier Greenspeed and Bryant Evolution Extreme 280ANV heat pumps sold from 2011 to 2016.

A manufacturer’s warranty pays for the part, not the labor. We read your serial number before ordering anything, so you know what’s covered.

Keep reading

Pages that go with a
Bryant repair

Other brands we repair

Every make we work on, in one place: the brands we repair.

Asked on the phone

Bryant questions,
answered straight

How much does a Bryant repair cost?

The diagnostic is $99. Most Bryant repairs run $95 to $1,500: a flame sensor cleaned is $95 to $180, an igniter $240 to $410, a capacitor $240 to $370, a control board $550 to $1,180. If it’s past fixing, a new Carrier or Trane furnace is $4,285 to $14,040 installed and a furnace with an AC is $8,898 to $23,000. From about $71 a month at 0% APR for 60 months, the whole price financed, on approved credit. How financing works

What does code 33 mean on a Bryant furnace?

Three short flashes, then three long: a switch in the furnace’s limit circuit opened, which usually means it ran too hot. Code 13 is the same switch held open over 3 minutes, and the furnace locks out. Carrier’s first check is a dirty filter or restricted ductwork, so change the filter, and call if 33 comes back. If the manual-reset rollout switch by the burners tripped, Bryant’s manual says to fix the cause before resetting it, and never to jumper it.

What does code 31 mean on a Bryant furnace?

A pressure switch is open, so the furnace won’t light. On the current condensing Bryants it’s the secondary pressure switch, and 31.3 means it locked out after three tries. Carrier’s own checklist: a plugged condensate drain, water sitting in the vent pipe, a blocked pressure tube or a failing inducer motor. A clogged drain is the cheap one, $175 to $420 to clear.

Is Bryant the same as Carrier?

Same company: Bryant is a Carrier company, and the two print the identical code table in their 2026 manuals for matching furnaces. The model numbers differ (a Bryant outdoor unit starts with 1 or 2, a Carrier with 24 to 27). A Bryant repair is priced exactly like a Carrier one.

What would you put in when my Bryant is done?

A Carrier or a Trane, priced side by side in writing. Bryant is a Carrier company, and we’re on Carrier’s dealer locator as Carrier experts.

Is Bryant a good brand?

Yes. In Consumer Reports’ 2022 central air survey, Bryant was one of five brands rated Excellent for owner satisfaction, and its top Evolution furnace is rated up to 98.5% AFUE. When one is done we’d still put in a Trane or a Carrier: Trane was the only brand in that survey rated Excellent for both reliability and owner satisfaction.

How do I tell how old my Bryant is?

Read the serial number on the outdoor unit’s rating plate, on the back near the service valves: the first two digits are the week and the next two the year, so 2218E… was built in week 22 of 2018. The furnace’s plate is inside its front door; date it by the outdoor unit or the install invoice.

Get the Bryant running

Call now, or tell us what
the Bryant is doing

No heat or no cooling, call: (703) 997-9757, 24/7. Not that urgent? Send the form at the top and the office calls or texts you back to set a time.

SwiftPro Heating, Cooling & Plumbing
4230 Lafayette Center Dr N, Chantilly, VA 20151
44679 Endicott Dr, Suite 211, Ashburn, VA 20147
Virginia Class A contractor license #2705192276

Repair prices are SwiftPro’s own, by part, in Northern Virginia; yours is quoted in writing after the diagnostic. Replacement prices are our installed ranges by system size.

Bryant, Evolution and Red Shield are trademarks of Carrier Corporation.

Call Now Book Online
5.01,132 reviews